Product Description:
Patented HVE Suction Dental Mirror System
The HVE Suction Dental Mirror system features a patented design that combines an Ultra High Definition front surface alloy-coated mirror lens with an industry-leading reflectance rate of 98%. This innovative system offers unmatched working visibility and isolation, enhancing efficiency without distractions.
Equipped with quick-connect HVE tubing, the system allows for seamless integration into your HVE unit (11mm or 16mm standard) in just seconds. The lightweight 3-Axis rotation connection enables 360-degree free rotation of the mirror handle, ensuring minimal drag and effortless maneuverability.
Key Features:
-
Powerful Suction: The mirror integrates 20 strategically placed suction holes around the lens and on the back of the mirror face, delivering effective control over aerosols and spatter.
-
Slim Design: With a working end measuring only 5.5mm—the thinnest in the dental industry—it ensures ease of use and accessibility during procedures.
-
Efficient Replacement System: The patented 1-Click mirror replacement system allows for quick and cost-effective mirror lens replacements, ensuring continued performance as needed.
-
Durability and Autoclavability: The dental mirrors are autoclavable up to 135°C, providing reliable sterilization. While durable, the plastic components may require replacement over time due to fatigue.
-
Quick-Disconnect Design: The mirrors can be detached from the HVE tubing in seconds thanks to the streamlined quick-connect mechanism.
-
Compact Mirror Lens: The lens measures 23mm, delivering precision and clarity for dental procedures.
The HVE Suction Dental Mirror system is designed to meet the demands of modern dental practices, combining innovation, efficiency, and practicality to enhance both safety and workflow.
Product Includes:
- Assorted Color HVE Suction Dental Mirrors: Qty 5 (five)
- Replacement Mirror Lenses & Silicone Plugs: Qty 4 (four)
- Replacement Mirror Key: Qty 1 (one)
- HVE Air Connections & Tubing Kit: Qty 2(two)
- Instructions for Use
Enhance Efficiency and Reduce Infectious Aerosols in Your Dental Office with the HVE Suction Dental Mirror
Recent studies have highlighted that dental offices fall among the highest-risk environments for the transmission of COVID-19 and other airborne diseases. The close face-to-face interaction with patients, exposure to bodily fluids, and the aerosolization of these fluids during routine dental procedures all contribute to heightened risks for dental professionals, staff, and patients alike.
Extensive research has demonstrated that proper high-volume suction during dental procedures can eliminate over 90% of aerosols generated in the process. The use of High Volume Evacuation (HVE) has been proven to significantly reduce aerosols and spatter, thereby decreasing the transmission of communicable diseases from patients to staff and clinicians.
Studies also indicate that aerosol particles containing infectious agents tend to remain within 36 inches of the patient’s face during procedures—precisely within the working area of dental professionals. These aerosolized particles and spatter pose a serious health risk to anyone operating within this proximity.
To mitigate these risks, the M7 HVE Mirror provides a straightforward and cost-effective solution for protecting your practice. This innovative dental mirror integrates continuous suction with 20 strategically placed HVE holes around the lens and on the back of the mirror head, effectively controlling dental aerosols while maintaining standard functionality. By simply connecting the M7 HVE Mirror to your existing HVE valve, it can be seamlessly incorporated into your practice in seconds.
While reducing aerosols is not the sole precaution necessary in dental offices, implementing the M7 HVE Mirror alongside other recommended PPE measures is a proactive step toward safeguarding the health of your staff and patients. Empower your dental practice by maximizing the potential of the tools you already use and prioritizing safety with effective aerosol reduction methods, backed by documented research.

Introduce your content
Answer your customers' common questions
How to care for your mirror
Our mirror handles have an average life span of 300 autoclave cycles with Class B autoclaves at 135 degrees centigrade. But even so, It's easy to give your mirrors TLC to make it last longer:
1. Put the cover on after use, before washing, during soaking and sterilization and in storage.
2. Avoid dropping the mirrors.
3. Prior to patient use, make sure that the mirror lens is secured in place. Please check carefully if the lens are placed properly to avoid the lens popping out of the handle. Please make sure the lens is flushed into the handle. Please tap the head of the mirror to check if the lens will loosely pop out. If this is so, please get a new handle already.
4. Use the recommended solutions to clean and disinfect the mirrors (ex. Enzymatic solution)
5. Always pack the mirrors in autoclave pouches and avoid the mirrors to touch the hottest areas of the autoclave.
6. For new mirrors, do not remove the lenses without prior autoclave sterilization.
7. For M1 Light source, please use rechargeable AAA batteries and avoid leaving batteries in the module. Never forget to remove after use. Never soak in Liquid and Never Autoclave or sterilize. Avoid dropping them as well. Like any light source, bulbs can break when dropped. Be careful.
When your mirror handle has aged and gone through a lot of autoclave cycles, it is time to change the handle.
Disinfection and Sterilization
Pre washing with dishwashing soap and smooth, soft sponge or even just the handler's fingers may be done to remove surface debris.
Composites and Bonding agents that may have stuck on the mirror may be cleaned with alcohol based rapid disinfectant such as Deconex Solarsept.
We recommend Deconex Instrument Plus to soak the mirrors in.
The whole mirror can be soaked in enzymatic solution and can be autoclaved except for M1 Bright LED light source module and batteries.
For M1, PLEASE REMOVE THE LIGHT SOURCE IMMEDIATELY AFTER USE OR PRIOR TO SOAKING/WASHING OR DISINFECTION. Light source module can be wiped with disinfectant alcohol wipes ONLY.
For M7, It is best to suction water after use to help clean walls of the hose, before soaking in enzymatic solution. Please use a hose/straw brush to avoid biofilm build up inside the hose's walls and the lumen of the M7 handle while cleaning with enzymatic solution.
You may also remove the mirror lens to thoroughly clean the handle of blood, plaque debris and saliva.
Mirror Replacement
WHEN DO YOU KNOW WHEN IT IS TIME TO REPLACE THE MIRROR?
1. For handles, when the lenses get loose without active removal. If your mirror handle has gone through its life span or the lens has been changed several times, tap the mirror handle head with enough force, if the lens falls out, its time to change the mirror.
2. For lenses, when antifog coating has worn out due to sterilization. Also, when there are obvious signs of scratches that make the lens blurry.
HOW TO REPLACE THE LENS:
It is easy to remove and replace the mirror lenses. Please watch this video for demonstration: https://youtu.be/AiGSYdNFgwM
REMINDERS AFTER REPLACING THE LENS:
1. Always make sure that you have placed the mirror lens correctly and securely.
2. Always use the replacement key to properly secure the mirror lens and return the small black silicone plug in place.
3. Please check carefully if the lens are placed properly to avoid the lens popping out of the handle. Please make sure the lens is flushed into the handle. Please tap the head of the mirror to check if the lens will loosely pop out. If this is so, please get a new handle already.
4. When your mirror handle has aged and gone through a lot of autoclave cycles, it is time to change the handle.
For M2 Magnifying mirrors, we do not recommend to replace lenses and we do not have spare lenses available.
Disposal
We take responsibility for our environment, and for this purpose, we reduce waste as much as possible by our productive activities.
Most products from Motranser are also made of recyclable materials. It is eco-friendly.
The handles can be disposed of as recyclable plastics.
Mirror lenses can be disposed together with your sharps.
Disinfection and Sterilization
Pre washing with dishwashing soap and smooth, soft sponge or even just the handler's fingers may be done to remove surface debris.
Composites and Bonding agents that may have stuck on the mirror may be cleaned with alcohol based rapid disinfectant such as Deconex Solarsept.
We recommend Deconex Instrument Plus to soak the mirrors in.
The whole mirror can be soaked in enzymatic solution and can be autoclaved except for M1 Bright LED light source module and batteries.
For M1, PLEASE REMOVE THE LIGHT SOURCE IMMEDIATELY AFTER USE OR PRIOR TO SOAKING/WASHING OR DISINFECTION. Light source module can be wiped with disinfectant alcohol wipes ONLY.
For M7, It is best to suction water after use to help clean walls of the hose, before soaking in enzymatic solution. Please use a hose/straw brush to avoid biofilm build up inside the hose's walls and the lumen of the M7 handle while cleaning with enzymatic solution.
You may also remove the mirror lens to thoroughly clean the handle of blood, plaque debris and saliva.
Mirror Replacement
WHEN DO YOU KNOW WHEN IT IS TIME TO REPLACE THE MIRROR?
1. For handles, when the lenses get loose without active removal. If your mirror handle has gone through its life span or the lens has been changed several times, tap the mirror handle head with enough force, if the lens falls out, its time to change the mirror.
2. For lenses, when antifog coating has worn out due to sterilization. Also, when there are obvious signs of scratches that make the lens blurry.
HOW TO REPLACE THE LENS:
It is easy to remove and replace the mirror lenses. Please watch this video for demonstration: https://youtu.be/AiGSYdNFgwM
REMINDERS AFTER REPLACING THE LENS:
1. Always make sure that you have placed the mirror lens correctly and securely.
2. Always use the replacement key to properly secure the mirror lens and return the small black silicone plug in place.
3. Please check carefully if the lens are placed properly to avoid the lens popping out of the handle. Please make sure the lens is flushed into the handle. Please tap the head of the mirror to check if the lens will loosely pop out. If this is so, please get a new handle already.
4. When your mirror handle has aged and gone through a lot of autoclave cycles, it is time to change the handle.
For M2 Magnifying mirrors, we do not recommend to replace lenses and we do not have spare lenses available.