Product Description:
This 23mm LED Smart Mouth Mirror integrates cutting-edge design with advanced functionality to enhance clinical efficiency and visibility. It features an Ultra High Definition front surface alloy-coated mirror lens with an industry-leading reflectance rate of 98%. Paired with a super bright 65,000-lux interchangeable white LED light source, this mirror delivers unparalleled working visibility during dental procedures.
Key Features:
-
Optimal Visibility and Hygiene: The LED light source is easily inserted into the autoclavable mirror handles, ensuring superior infection control and ease of use.
-
Durable Design: The LED Dental Mirror handles are autoclavable up to 500 cycles at 135°C, providing long-lasting reliability.
-
Patented Replacement System: The mirror utilizes a patented 1-Click replacement system, allowing for quick and efficient mirror lens replacements using a specialized key.
Performance and Power:
-
Brightness: The white LED light offers up to 65,000 lux of brightness, ensuring exceptional visibility.
-
Battery Power: Operates on two AAA batteries (alkaline or rechargeable) with a performance runtime of up to 6 hours.
-
Disinfection and Sterilization Guidelines: Before soaking or autoclaving, remove the light module and batteries. Only the mirror handle and tail cap are suitable for sterilization. Detach the tail cap to allow sterilization solution and steam to reach the handle interior effectively.
Note: The light source module and batteries should not be soaked and autoclaved.
Product Includes:
-
- Assorted Color Dental Mirror Handle with tail cap: Qty 5 (five)
- Spare mirror lens with rubber stops: Qty 4 (four)
- LED Light Source Module: Qty 1 (one)
- Replacement Key:Qty 1 (one)
- Instructions for Use
-
Important Notice: All sales are final. Returns are not accepted for this product.
Introduce your content
Answer your customers' common questions
How to care for your mirror
Our mirror handles have an average life span of 300 autoclave cycles with Class B autoclaves at 135 degrees centigrade. But even so, It's easy to give your mirrors TLC to make it last longer:
1. Put the cover on after use, before washing, during soaking and sterilization and in storage.
2. Avoid dropping the mirrors.
3. Prior to patient use, make sure that the mirror lens is secured in place. Please check carefully if the lens are placed properly to avoid the lens popping out of the handle. Please make sure the lens is flushed into the handle. Please tap the head of the mirror to check if the lens will loosely pop out. If this is so, please get a new handle already.
4. Use the recommended solutions to clean and disinfect the mirrors (ex. Enzymatic solution)
5. Always pack the mirrors in autoclave pouches and avoid the mirrors to touch the hottest areas of the autoclave.
6. For new mirrors, do not remove the lenses without prior autoclave sterilization.
7. For M1 Light source, please use rechargeable AAA batteries and avoid leaving batteries in the module. Never forget to remove after use. Never soak in Liquid and Never Autoclave or sterilize. Avoid dropping them as well. Like any light source, bulbs can break when dropped. Be careful.
When your mirror handle has aged and gone through a lot of autoclave cycles, it is time to change the handle.
Disinfection and Sterilization
Pre washing with dishwashing soap and smooth, soft sponge or even just the handler's fingers may be done to remove surface debris.
Composites and Bonding agents that may have stuck on the mirror may be cleaned with alcohol based rapid disinfectant such as Deconex Solarsept.
We recommend Deconex Instrument Plus to soak the mirrors in.
The whole mirror can be soaked in enzymatic solution and can be autoclaved except for M1 Bright LED light source module and batteries.
For M1, PLEASE REMOVE THE LIGHT SOURCE IMMEDIATELY AFTER USE OR PRIOR TO SOAKING/WASHING OR DISINFECTION. Light source module can be wiped with disinfectant alcohol wipes ONLY.
For M7, It is best to suction water after use to help clean walls of the hose, before soaking in enzymatic solution. Please use a hose/straw brush to avoid biofilm build up inside the hose's walls and the lumen of the M7 handle while cleaning with enzymatic solution.
You may also remove the mirror lens to thoroughly clean the handle of blood, plaque debris and saliva.
Mirror Replacement
WHEN DO YOU KNOW WHEN IT IS TIME TO REPLACE THE MIRROR?
1. For handles, when the lenses get loose without active removal. If your mirror handle has gone through its life span or the lens has been changed several times, tap the mirror handle head with enough force, if the lens falls out, its time to change the mirror.
2. For lenses, when antifog coating has worn out due to sterilization. Also, when there are obvious signs of scratches that make the lens blurry.
HOW TO REPLACE THE LENS:
It is easy to remove and replace the mirror lenses. Please watch this video for demonstration: https://youtu.be/AiGSYdNFgwM
REMINDERS AFTER REPLACING THE LENS:
1. Always make sure that you have placed the mirror lens correctly and securely.
2. Always use the replacement key to properly secure the mirror lens and return the small black silicone plug in place.
3. Please check carefully if the lens are placed properly to avoid the lens popping out of the handle. Please make sure the lens is flushed into the handle. Please tap the head of the mirror to check if the lens will loosely pop out. If this is so, please get a new handle already.
4. When your mirror handle has aged and gone through a lot of autoclave cycles, it is time to change the handle.
For M2 Magnifying mirrors, we do not recommend to replace lenses and we do not have spare lenses available.
Disposal
We take responsibility for our environment, and for this purpose, we reduce waste as much as possible by our productive activities.
Most products from Motranser are also made of recyclable materials. It is eco-friendly.
The handles can be disposed of as recyclable plastics.
Mirror lenses can be disposed together with your sharps.
Disinfection and Sterilization
Pre washing with dishwashing soap and smooth, soft sponge or even just the handler's fingers may be done to remove surface debris.
Composites and Bonding agents that may have stuck on the mirror may be cleaned with alcohol based rapid disinfectant such as Deconex Solarsept.
We recommend Deconex Instrument Plus to soak the mirrors in.
The whole mirror can be soaked in enzymatic solution and can be autoclaved except for M1 Bright LED light source module and batteries.
For M1, PLEASE REMOVE THE LIGHT SOURCE IMMEDIATELY AFTER USE OR PRIOR TO SOAKING/WASHING OR DISINFECTION. Light source module can be wiped with disinfectant alcohol wipes ONLY.
For M7, It is best to suction water after use to help clean walls of the hose, before soaking in enzymatic solution. Please use a hose/straw brush to avoid biofilm build up inside the hose's walls and the lumen of the M7 handle while cleaning with enzymatic solution.
You may also remove the mirror lens to thoroughly clean the handle of blood, plaque debris and saliva.
Mirror Replacement
WHEN DO YOU KNOW WHEN IT IS TIME TO REPLACE THE MIRROR?
1. For handles, when the lenses get loose without active removal. If your mirror handle has gone through its life span or the lens has been changed several times, tap the mirror handle head with enough force, if the lens falls out, its time to change the mirror.
2. For lenses, when antifog coating has worn out due to sterilization. Also, when there are obvious signs of scratches that make the lens blurry.
HOW TO REPLACE THE LENS:
It is easy to remove and replace the mirror lenses. Please watch this video for demonstration: https://youtu.be/AiGSYdNFgwM
REMINDERS AFTER REPLACING THE LENS:
1. Always make sure that you have placed the mirror lens correctly and securely.
2. Always use the replacement key to properly secure the mirror lens and return the small black silicone plug in place.
3. Please check carefully if the lens are placed properly to avoid the lens popping out of the handle. Please make sure the lens is flushed into the handle. Please tap the head of the mirror to check if the lens will loosely pop out. If this is so, please get a new handle already.
4. When your mirror handle has aged and gone through a lot of autoclave cycles, it is time to change the handle.
For M2 Magnifying mirrors, we do not recommend to replace lenses and we do not have spare lenses available.